THE COUNCIL FOR INDUSTRIAL &
SCIENTIFIC RESEARCH PILOT PLANT – GYPSLIM PLANT |
|
 |
The Gypslim Plant (operational since 5 March
2008) which uses the Gypslim process (patented, designed
and operated by the CSIR) to produce “Industrial” quality
water at a processing rate of one cubic metre per hour.
|
|
|
|
|
|
THE SAVMIN PILOT PLANT |
|
 |
The SAVMIN Plant (operational since 5 April
2008) uses the SAVMIN methodology (patented by Mintek and
operated by Atomaer RSA (Pty) Ltd) to treat 4 cubic metres of
AMD per hour to “industrial” quality standards.
|
|
|
|
|
|
THE BY-PRODUCT RECOVERY PLANT |
|

 |
The By-Product Recovery Plant (operational
since 10 March 2008 and designed, engineered and operated by the
CSIR, Key Structure Holdings and Sulphidetech) which processes
and isolates by-products produced by the SAVMIN and Gypslim
water treatment processes.
|
|
|
|
|
|
|
TREATED WATER FROM THE GYPSLIM
PROCESS |
|
 |
The below picture gives an indication of the
result that we are currently able to achieve with the Gypslim
process. The table is an extract of the actual results, measured
against the required standards. |
|
|
|
|
|
Criteria |
|
SANAS Class II
Specification |
Feed Water |
Product Water |
|
pH |
|
4-10 |
3.35 |
7.9 |
|
Total Alkalinity (TAlk) |
mg/l as CaCO3 |
No Spec |
0 |
140 |
|
Aluminium (Al) |
mg/l |
0.5 |
2.97 |
0.01 |
|
Sodium (Na) |
mg/l |
400 |
46.5 |
53.2 |
|
Potassium (K) |
mg/l |
100 |
4.4 |
4.8 |
|
Calcium (Ca) |
mg/l |
300 |
205 |
75 |
|
Magnesium (Mg) |
mg/l |
100 |
124.6 |
0.98 |
|
Total Iron (Fe) |
mg/l |
2 |
182 |
0.3 |
|
Manganese (Mn) |
mg/l |
1 |
63.7 |
0.09 |
|
Sulphate (SO4) |
mg/l |
600 |
1910 |
90 |
|
Chloride (Cl) |
mg/l |
600 |
44.5 |
49.5 |
|
Fluoride (F) |
mg/l |
5 |
5.4 |
0.07 |
|
Silicon (Si) |
mg/l |
No Spec |
11 |
0.45 |
|
|
|